https://www.selleckchem.com/products/nlg919.html
To describe a rare complication of phacoemulsification (Phaco) cataract extraction. A phaco tip fracture occurred during the sculpting of the nucleus in a cataract extraction surgery of a 60-year-old woman. The surgeon introduced the second instrument through the side port to retrieve the broken portion of the tip while maintaining it inside the sleeve. Phaco tip fracture is a rare but serious complication that all cataract surgeons should be able to manage safely. Main risk factors for phaco tip fractures are Aspiration Bypass System (A