Fabric filters are generally used to eliminate the particulate matter of flue gas that is generated from waste incinerators. The pressure drop of fabric filter (ΔP) is accompanied by the build-up of a dust layer on the fabric filter, and ΔP increase leads to an increase in the energy consumption of induced draft fan in an incineration facility. In this study, phosphoric acid (H3PO4) and monobasic calcium phosphate (Ca(H2PO4)2) are tested as chemicals to reduce ΔP in fabric filter using a laboratory-scale equipment. The