https://www.selleckchem.com/products/cc-90011.html
To develop the surface-treated metal implant with highly encouraged positive properties, including high anti-corrosiveness, bio-activeness and bio-compatibleness for orthopedic applications. In this work, the surface of commercially pure titanium (Ti) metal was treated with bio-compatible polydopamine (PD) by merely immersing the Ti plate in PD solution. The composite of trivalent lanthanide minerals (La , Ce and Gd )-substituted hydroxyapatite (MHAP) with (AV) gel was prepared and coated on the PD-Ti plate by electrophoretic depositio